Skip to content

About

Switch a Weheat heat pump between its heating curve and OpenTherm from Homey (experimental)

Resources

Stars

0 stars

Watchers

0 watching

Forks

Latest commit

 

History

11 Commits

Folders and files

Repository files navigation

WeHeat-Control

English | Nederlands

Switch a Weheat heat pump between its heating curve and OpenTherm from Homey (or the command line), on your own network.

Why would you want this?

A Weheat heat pump has no real off switch. On its heating curve it keeps making heat whenever the outside temperature asks for it, whatever electricity costs at that moment.

That matters with a dynamic energy contract, where the price changes every hour. On a cold winter evening a few hours can cost several times the average, and those are often exactly the hours the heat pump runs hardest. A well-insulated house can easily coast through a few hours without heating, so you'd rather stop the pump then and heat when electricity is cheap again.

The trick, if you have an OpenTherm room thermostat connected to the heat pump:

  1. Normally the pump runs on its heating curve.
  2. Before the expensive hours, switch it to OpenTherm: now the thermostat decides. Set the thermostat to a very low temperature and it tells the heat pump there's no heat needed, so the pump stops heating.
  3. When prices are back to normal, switch it back to the heating curve. WeHeat-Control puts back exactly the curve you had.

WeHeat-Control does steps 2 and 3 on a single call from Homey, so a Homey flow can do it automatically, for example on a price trigger from your energy supplier's app. (Turning the thermostat down and up is up to you or your Homey flow; this script only switches the heat pump's control mode.)

Weheat is working on smarter control of its own ("Weheat Intelligence"). Until that's available, this trick lets you turn the heat pump off during expensive hours.

The two modes

Mode What the pump does
curve Runs on its heating curve: the water temperature follows the outside temperature (ControlMethod 1). Going back to curve puts back exactly the curve points it had before.
opentherm The OpenTherm room thermostat decides (ControlMethod 4).

Homey sends POST http://<server>:8095/api/mode with {"mode": "opentherm"} or {"mode": "curve"}.

Experimental. This uses the API Weheat's own web portal uses (https://api.weheat.nl/api/v1). It's not a documented public API and may change without notice. It changes settings on the heat pump: use it on your own pump only, and check the result in the Weheat app the first times.

How it works

  1. Login. It logs in to the Weheat portal (portal.weheat.nl) with your own Weheat username and password, the way a browser does: the portal's sign-in, Weheat's login page (auth.weheat.nl), back to the portal, and then the portal session's token (about 5 minutes; renewed by itself, a new login when needed). Weheat's settings API only accepts the portal's own token: a token from the official third-party API gets "This endpoint is not available for third-party API clients". (That official API is read-only; find also uses it.)

  2. Read. GET /api/v1/installations/<installation>/settings returns the pump's settings, including ControlMethod (1 = heating curve, 4 = OpenTherm) and HeatingCurveY (the curve points).

  3. Remember. Each time it leaves the heating curve, it first saves the curve points in state.json. It refuses to switch if it can't read them, so it can always go back.

  4. Switch. PATCH /api/v1/control-boards/<control board>/settings:

    • OpenTherm: {"settings":{"ControlMethod":4},"updateImmediately":false}
    • back to the curve: {"settings":{"ControlMethod":1,"HeatingCurveY":[44.1,28,24,19,18]},"updateImmediately":false} (the remembered points)

    A mode the pump is already in sends nothing.

Install

On a computer that's always on, on the same network as Homey (a Raspberry Pi or a small Linux server). Needs Python 3.10 or newer. The code is at https://github.com/techkelder/WeHeat-Control.

git clone https://github.com/techkelder/WeHeat-Control.git weheat-control
cd weheat-control
python3 -m venv .venv
.venv/bin/pip install -r requirements.txt
cp config.example.json config.json
chmod 600 config.json

Fill in config.json:

Setting What
username, password Your Weheat login (the same as in the Weheat app).
installation_id Leave empty: find fills it in. Or copy it from the portal's address bar (portal.weheat.nl/.../installations/<id>/...).
control_board_id Leave empty: find fills it in when it can. Otherwise: open the portal in Chrome, developer tools (F12) → Network, change a setting, and look at the control-boards/<id>/settings request.
update_immediately false, what the portal sends: the pump takes the change at its next sync.
api_host, api_port Where the API listens (default all network cards, port 8095).
api_token Optional. When set, Homey must send it (see below). Recommended.
state_file Tokens, ids and the remembered curve (default state.json).

config.json and state.json hold your password and tokens. They're in .gitignore; never share them.

Step 1: try it (read only)

.venv/bin/python weheat_control.py login          # can we log in?
.venv/bin/python weheat_control.py find           # installation and control board
.venv/bin/python weheat_control.py status         # mode, curve, what's remembered
.venv/bin/python weheat_control.py status --raw   # every setting, as Weheat sends it

Step 2: switch by hand

.venv/bin/python weheat_control.py save                      # remember the curve now
.venv/bin/python weheat_control.py mode opentherm --dry-run  # only show what would be sent
.venv/bin/python weheat_control.py mode opentherm
.venv/bin/python weheat_control.py mode curve

Then check in the Weheat app that the pump did what you expected. If you change the curve yourself later, that's fine: the curve is saved again each time the pump leaves it.

Step 3: the API for Homey

.venv/bin/python weheat_control.py serve
Request What
POST /api/mode with {"mode": "opentherm"} Switch to OpenTherm
POST /api/mode with {"mode": "curve"} Back to the heating curve (the remembered points)
GET /api/mode Now: control method, curve, last mode, the remembered curve
GET /api/health {"ok": true}; no token needed

Answers are JSON, for example {"changed": true, "mode": "opentherm", "sent": {"ControlMethod": 4}, "ok": true}. A wrong body gives HTTP 400; a problem with Weheat gives HTTP 502 with {"error": "..."}.

The API token

The api_token is only between Homey and this script. Weheat never sees it.

  • What it is: a made-up shared password, api_token in config.json. The script checks it on every request. Without it, or with a wrong one, it answers 401 and changes nothing. Only GET /api/health works without it.
  • Why: without it, anyone on the network who knows the address could switch the heat pump.
  • Where it goes: put the same value in the Homey flow, as the header Authorization: Bearer <api_token>, or as ?token=<api_token> at the end of the address (for cards that can't set headers).
  • Separate from the Weheat login: the script logs in to Weheat by itself with the username and password in config.json, and keeps that Weheat token to itself. Homey never needs your Weheat password.
  • Leaving it empty turns the check off: the script logs a warning at start-up, and anyone on the network can switch the pump. Not recommended.

Make up your own long random text, for example:

python3 -c "import secrets; print(secrets.token_urlsafe(24))"

In Homey

HomeyScript (a "Run a script with argument" card; the argument is opentherm or curve):

const BASE = "http://192.168.1.20:8095";   // the computer running WeHeat-Control
const TOKEN = "your api_token";            // or "" without a token

const mode = args[0];                      // "opentherm" or "curve"
const r = await fetch(`${BASE}/api/mode`, {
  method: "POST",
  headers: { "Content-Type": "application/json", ...(TOKEN ? { Authorization: `Bearer ${TOKEN}` } : {}) },
  body: JSON.stringify({ mode }),
});
const answer = await r.json();
if (!r.ok) throw new Error(answer.error);
return answer.mode;

Without scripting, use an HTTP request card (for example from the "HTTP request flow cards" app): method POST, address http://192.168.1.20:8095/api/mode?token=<your api_token>, body {"mode": "opentherm"} (or "curve"), content type application/json.

Plain HTTP: keep the API on your own network, don't forward the port to the internet.

Keep it running (Linux, systemd)

/etc/systemd/system/weheat-control.service:

[Unit]
Description=WeHeat-Control API
After=network-online.target
Wants=network-online.target

[Service]
WorkingDirectory=/opt/weheat-control
ExecStart=/opt/weheat-control/.venv/bin/python weheat_control.py serve
Restart=on-failure
User=weheat

[Install]
WantedBy=multi-user.target
sudo systemctl enable --now weheat-control
journalctl -u weheat-control -f        # every switch is logged

Disclaimer

WeHeat-Control is a personal project. It isn't made, supported or endorsed by Weheat. It uses Weheat's portal API, which isn't a public API, so it can stop working whenever Weheat changes something, and using it may not be what Weheat intends.

You use it at your own risk. It only switches the heat pump between two modes Weheat itself offers, but you're responsible for how you use it: check that your house stays warm enough, that the pump goes back to its heating curve, and that the result is what you expect. The author can't be held responsible for any damage, costs or other consequences of using this software, such as a cold house, a missed switch back, higher energy costs or problems with your Weheat account or warranty.

License

MIT, see LICENSE: free to use, change and share, provided "as is", without warranty or liability.