13 changes: 12 additions & 1 deletion CHANGELOG.md
Original file line number Diff line number Diff line change
@@ -1,5 +1,17 @@
# Changelog

## heishamon 0.8.0

Read `hp_power_w` from `main/Heat_Power_Consumption` (TOP16), with a
`power_topic` override. This is the heat-mode input, not total electrical
input in cooling or DHW mode. The new reading remains unverified on
hardware. Invalid negative or non-finite power values clear the reading;
newer pumps can send −200 on this legacy topic. Power expires after
60 seconds without its own update, even if other topics keep arriving.

Use `hp_outdoor_temp_c` for outdoor temperature, matching the other
heat-pump drivers and FTW's Heating view. Prior history keeps its old key.

## heishamon 0.7.0

Declare the existing `set_heat_curve_offset` control: −3…+3 °C, in steps
Expand Down Expand Up @@ -315,7 +327,6 @@ Driver versions follow [Semantic Versioning](https://semver.org/spec/v2.0.0.html
comments. No behaviour change.

### Added

- **acuvim** 0.4.1 — Accuenergy Acuvim II three-phase revenue-grade meter,
migrated from the Blixt L1 driver source (POI meter on Blixt
SvK sites). One bundled FC03 float32 block + a bounded probe of the
Expand Down
4 changes: 2 additions & 2 deletions SUPPORT_STATUS.md
Original file line number Diff line number Diff line change
Expand Up @@ -76,8 +76,8 @@ Catalog source is not proof that a target can install or run a driver.
| growatt | 2.1.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| hardybarth | 1.0.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| hardybarth | 1.0.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| heishamon | 0.7.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| heishamon | 0.7.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| heishamon | 0.8.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| heishamon | 0.8.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| hello | 1.1.2 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| hello | 1.1.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| huawei | 2.1.3 | ftw-core | not_assessed | — | not_recorded | not_assessed |
Expand Down
2 changes: 1 addition & 1 deletion devices.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -1008,7 +1008,7 @@ manufacturers:
protocols:
- protocol: mqtt
driver: "heishamon"
version: "0.7.0"
version: "0.8.0"
ders: [heatpump]
control: true
firmware_versions: ""
Expand Down
48 changes: 42 additions & 6 deletions drivers/lua/heishamon.lua
Original file line number Diff line number Diff line change
Expand Up @@ -24,14 +24,22 @@
-- min_offset: -3
-- max_offset: 3
-- safe_offset: 0
-- power_topic: Heat_Power_Consumption
--
-- power_topic names a main/ topic carrying electrical power in W.
-- The default is Heat_Power_Consumption (TOP16), the heat-mode input.
-- It is not total input in cooling or DHW mode. Pumps with an extra data
-- block can send invalid negative values on this legacy topic; omit them.
-- This new reading has not been checked on hardware.
-- Source: https://github.com/heishamon/HeishaMon/blob/main/MQTT-Topics.md

DRIVER = {
host_api_min = 1,
host_api_max = 1,
id = "heishamon",
name = "Panasonic Aquarea (Heishamon)",
manufacturer = "Panasonic",
version = "0.7.0",
version = "0.8.0",
protocols = { "mqtt" },
capabilities = { "heatpump" },
description = "Panasonic Aquarea H/J/K/L/M-series heat pump via Heishamon MQTT bridge. Controls Zone 1 heat curve offset (Z1_Heat_Request_Temp) in range -3..+3 °C.",
Expand All @@ -41,7 +49,7 @@ DRIVER = {
verification_status = "experimental",
verified_by = { "Rolf (Runneval)" },
verified_at = "2026-06-21",
verification_notes = "Tested on WH-SXC09H3E8 (H-series) with Heishamon Large v4.1.6 on ESP32. MQTT via core-mosquitto on HA Green. Live metrics confirmed. Offset control verified via Z1_Heat_Request_Temp.",
verification_notes = "Existing metrics and offset control tested on WH-SXC09H3E8 (H-series) with Heishamon Large v4.1.6 on ESP32 on 2026-06-21. The new hp_power_w reading is not hardware-verified; its default topic reports heat-mode input, not total input in cooling or DHW mode.",
-- What an operator may command, in terms a host UI can render without
-- knowing this driver. The bounds are the defaults below; min_offset and
-- max_offset can narrow them in config, and driver_command clamps to
Expand Down Expand Up @@ -71,14 +79,17 @@ local outlet_temp = nil
local inlet_temp = nil
local target_temp = nil
local z1_offset = nil
local power_w = nil
local last_msg_ts = 0
local last_power_ts = 0
local STALE_AFTER_MS = 60000

-- Config (overridable via config.yaml)
local base_topic = "panasonic_heat_pump"
local min_offset = -3
local max_offset = 3
local safe_offset = 0
local power_topic = "Heat_Power_Consumption"

----------------------------------------------------------------------------
-- Lifecycle
Expand All @@ -92,6 +103,7 @@ function driver_init(config)
if config.min_offset then min_offset = tonumber(config.min_offset) or -3 end
if config.max_offset then max_offset = tonumber(config.max_offset) or 3 end
if config.safe_offset then safe_offset = tonumber(config.safe_offset) or 0 end
if config.power_topic then power_topic = config.power_topic end
end

-- Subscribe broadly to all Heishamon topics
Expand All @@ -104,7 +116,8 @@ function driver_init(config)

host.log("info", "Heishamon: initialized, base_topic=" .. base_topic
.. " offset_range=[" .. min_offset .. ".." .. max_offset .. "]"
.. " safe_offset=" .. safe_offset)
.. " safe_offset=" .. safe_offset
.. " power_topic=" .. power_topic)
end

function driver_poll()
Expand All @@ -114,7 +127,18 @@ function driver_poll()

for _, msg in ipairs(messages) do
local val = tonumber(msg.payload)
if val ~= nil then
if msg.topic == base_topic .. "/main/" .. power_topic then
-- Heat consumption cannot be negative. Some newer pumps use
-- -200 as an invalid value on the legacy power topic.
if val ~= nil and val == val and val >= 0 and val < math.huge then
power_w = val
last_power_ts = now
last_msg_ts = now
else
power_w = nil
last_power_ts = 0
end
elseif val ~= nil then
if msg.topic == base_topic .. "/main/Outside_Temp" then
outside_temp = val
last_msg_ts = now
Expand Down Expand Up @@ -143,14 +167,24 @@ function driver_poll()
inlet_temp = nil
target_temp = nil
z1_offset = nil
power_w = nil
last_power_ts = 0
elseif last_power_ts > 0 and (now - last_power_ts) > STALE_AFTER_MS then
host.log("warn", "Heishamon: no power reading for "
.. tostring(STALE_AFTER_MS) .. " ms — power stale")
power_w = nil
last_power_ts = 0
end

-- Emit metrics
if outside_temp ~= nil then host.emit_metric("hp_outside_temp_c", outside_temp, "°C") end
-- Emit metrics. Names are the ones FTW's heating view reads: it finds a
-- heat pump by hp_power_w and charts the outdoor temperature under
-- hp_outdoor_temp_c, the same names nibe_local and myuplink report.
if outside_temp ~= nil then host.emit_metric("hp_outdoor_temp_c", outside_temp, "°C") end
if outlet_temp ~= nil then host.emit_metric("hp_outlet_temp_c", outlet_temp, "°C") end
if inlet_temp ~= nil then host.emit_metric("hp_inlet_temp_c", inlet_temp, "°C") end
if target_temp ~= nil then host.emit_metric("hp_target_temp_c", target_temp, "°C") end
if z1_offset ~= nil then host.emit_metric("hp_z1_heat_offset", z1_offset, "°C") end
if power_w ~= nil then host.emit_metric("hp_power_w", power_w, "W") end

return 5000
end
Expand Down Expand Up @@ -205,4 +239,6 @@ function driver_cleanup()
inlet_temp = nil
target_temp = nil
z1_offset = nil
power_w = nil
last_power_ts = 0
end
60 changes: 60 additions & 0 deletions drivers/tests/lua_harness/test_heishamon_power_freshness.lua
Original file line number Diff line number Diff line change
@@ -0,0 +1,60 @@
dofile("drivers/tests/lua_harness/host_mock.lua")
host.reset()
dofile("drivers/lua/heishamon.lua")
driver_init({})

host._mqtt_buffer = {
{
topic = "panasonic_heat_pump/main/Heat_Power_Consumption",
payload = "4200",
},
{
topic = "panasonic_heat_pump/main/Outside_Temp",
payload = "5",
},
}
driver_poll()

local fresh_power = host._metrics.hp_power_w
if fresh_power == nil or fresh_power.value ~= 4200 then
error("fresh Heishamon power reading was not emitted")
end

host._metrics = {}
host._millis_counter = 60100
host._mqtt_buffer = {{
topic = "panasonic_heat_pump/main/Outside_Temp",
payload = "6",
}}
driver_poll()

if host._metrics.hp_power_w ~= nil then
error("stale Heishamon power survived an unrelated fresh topic")
end

local fresh_outdoor = host._metrics.hp_outdoor_temp_c
if fresh_outdoor == nil or fresh_outdoor.value ~= 6 then
error("fresh unrelated Heishamon telemetry was dropped with stale power")
end

-- Newer heat pumps can send -200 on the old power topic. Invalid values
-- must clear the previous power reading while other measurements survive.
for _, invalid in ipairs({"-200", "nan", "1e99"}) do
host._metrics = {}
host._mqtt_buffer = {{topic="panasonic_heat_pump/main/Heat_Power_Consumption", payload="4200"}}
driver_poll()
assert(host._metrics.hp_power_w.value == 4200, "valid power did not recover")
host._metrics = {}
host._mqtt_buffer = {
{topic="panasonic_heat_pump/main/Heat_Power_Consumption", payload=invalid},
{topic="panasonic_heat_pump/main/Outside_Temp", payload="7"},
}
driver_poll()
assert(host._metrics.hp_power_w == nil, "invalid power was emitted: " .. invalid)
assert(host._metrics.hp_outdoor_temp_c.value == 7, "invalid power dropped outdoor temperature")
end

host._metrics = {}
host._mqtt_buffer = {{topic="panasonic_heat_pump/main/Heat_Power_Consumption", payload="0"}}
driver_poll()
assert(host._metrics.hp_power_w.value == 0, "measured zero power was dropped")
7 changes: 7 additions & 0 deletions drivers/tests/test_stale_reads.py
Original file line number Diff line number Diff line change
Expand Up @@ -28,6 +28,13 @@ def test_mqtt_driver_does_not_emit_cached_data_on_idle_poll(driver_name):
run_lua("drivers/tests/lua_harness/test_mqtt_stale.lua", driver_name)


def test_heishamon_power_freshness_is_not_extended_by_other_topics():
run_lua(
"drivers/tests/lua_harness/test_heishamon_power_freshness.lua",
"heishamon",
)


@pytest.mark.parametrize("app", ["ProEM", "MiniPMG3", "Plus2PM"])
def test_shelly_poll_emits_nothing_when_all_reads_fail(app):
run_lua("drivers/tests/lua_harness/test_shelly_failures.lua", app)
Expand Down
6 changes: 3 additions & 3 deletions index.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -331,15 +331,15 @@ drivers:
size_bytes: 2193
sha256: "517e086af899dc511c86b00460cd8ce052a8d4973edee8b018e5824d4b550d6e"
- name: "heishamon"
version: "0.7.0"
version: "0.8.0"
tier: core
protocol: mqtt
connectivity: local
setup: [bridge]
ders: [heatpump]
control: true
size_bytes: 7932
sha256: "aed6707a656a7e4e17c5edd00e8d081ed485b580d078173c13bdad75d9ffcaac"
size_bytes: 9855
sha256: "5c322f14e58a2b9aad900813bea9438127249ebae2e76a4208cd74536703d7b6"
- name: "hello"
version: "1.1.2"
tier: community
Expand Down
12 changes: 9 additions & 3 deletions manifests/heishamon.yaml
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
name: "heishamon"
version: "0.7.0"
version: "0.8.0"
tier: core
author: "Sourceful Labs AB"
protocol: mqtt
Expand All @@ -16,9 +16,15 @@ tested_devices:
notes: "Panasonic Aquarea H/J/K/L/M-series heat pump via Heishamon MQTT bridge. Controls Zone 1 heat curve offset (Z1_Heat_Request_Temp) in range -3..+3 °C."
min_driver_version: "0.4.0"
min_host_version: "2.0.0"
size_bytes: 7932
size_bytes: 9855
dkb_id: "heishamon"
sha256: "aed6707a656a7e4e17c5edd00e8d081ed485b580d078173c13bdad75d9ffcaac"
sha256: "5c322f14e58a2b9aad900813bea9438127249ebae2e76a4208cd74536703d7b6"
signature: ""

bytecode_sha256: ""

upstream_docs:
- url: "https://raw.githubusercontent.com/heishamon/HeishaMon/main/MQTT-Topics.md"
title: "HeishaMon MQTT topics"
kind: api_docs
url_stability: stable
2 changes: 1 addition & 1 deletion support-status.json
Original file line number Diff line number Diff line change
Expand Up @@ -758,7 +758,7 @@
},
{
"catalog_source": true,
"catalog_version": "0.7.0",
"catalog_version": "0.8.0",
"driver_id": "heishamon",
"targets": {
"blixt-l1": {
Expand Down