8 changes: 8 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -25,6 +25,14 @@ hears from the charger, so a steady charge stays measured. Missing power or
source time cannot confirm a command's effect. The live-status display and
polling rate stay unchanged.

## pixii 2.1.8

Preserve the sign of measured AC power from Pixii register 40083 for command
feedback. Hardware reports this value in FTW site signs already: charging is
positive and discharging is negative. Setpoint conversion, commands, heartbeat
and safety policy are unchanged. Verified against PowerShaper site telemetry
reported in #154; regression tests cover both charge and discharge signs.

## pixii 2.1.7

Read the setpoint on every poll, including outside troubleshooting mode. Emit
Expand Down
4 changes: 2 additions & 2 deletions SUPPORT_STATUS.md
Original file line number Diff line number Diff line change
Expand Up @@ -112,8 +112,8 @@ Catalog source is not proof that a target can install or run a driver.
| p1_hdlc | 2.0.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| p1_meter | 2.0.2 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| p1_meter | 2.0.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| pixii | 2.1.7 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| pixii | 2.1.7 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| pixii | 2.1.8 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| pixii | 2.1.8 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| pixii_pv | 0.3.2 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| pixii_pv | 0.3.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| remne_p1ib | 0.1.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
Expand Down
2 changes: 1 addition & 1 deletion devices.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -1032,7 +1032,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "pixii"
version: "2.1.7"
version: "2.1.8"
ders: [battery, meter]
control: false
firmware_versions: ""
Expand Down
8 changes: 4 additions & 4 deletions drivers/lua/pixii.lua
Original file line number Diff line number Diff line change
Expand Up @@ -29,7 +29,7 @@ DRIVER = {
id = "pixii",
name = "Pixii PowerShaper",
manufacturer = "Pixii",
version = "2.1.7",
version = "2.1.8",
protocols = { "modbus" },
capabilities = { "battery", "meter" },
description = "Pixii PowerShaper commercial battery storage via Modbus TCP.",
Expand Down Expand Up @@ -474,9 +474,9 @@ function driver_poll()
local battery = {
w = bat_w,
setpoint_w = setpoint_pixii_w and -setpoint_pixii_w,
-- SunSpec W is in the generator frame, like the setpoint: positive
-- means power out of the inverter. Site signs charge positive.
control_power_w = acw_regs and -ac_w,
-- The measured AC register already uses site signs on Pixii hardware:
-- charge positive, discharge negative. Do not invert it like the setpoint.
control_power_w = acw_regs and ac_w,
control_power_available = acw_regs ~= nil,
v = bat_v,
a = bat_a,
Expand Down
6 changes: 4 additions & 2 deletions drivers/tests/test_pixii_status.py
Original file line number Diff line number Diff line change
Expand Up @@ -102,8 +102,10 @@ def test_pixii_control_readback_without_troubleshooting():
local battery = poll(3)
assert(battery.setpoint_w == -1500, "setpoint must use site signs outside TS mode")
assert(battery.control_power_available == true)
-- SunSpec W is generator frame: -1400 W flows into the inverter, a charge.
assert(battery.control_power_w == 1400, "command feedback must use site-signed AC, not DC")
assert(battery.control_power_w == -1400, "negative measured AC must remain discharge")
host._modbus_registers.holding[40083] = 1400
battery = poll(3)
assert(battery.control_power_w == 1400, "positive measured AC must remain charge")
host._modbus_read_fail_addresses[39905] = "timeout"
host._modbus_read_fail_addresses[40083] = "timeout"
battery = poll(3)
Expand Down
6 changes: 3 additions & 3 deletions index.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -498,14 +498,14 @@ drivers:
size_bytes: 19344
sha256: "29f2bd2f73c0d39d809839ca60b40c3e4281f1dda267ba2b26e66bd9ab80c27b"
- name: "pixii"
version: "2.1.7"
version: "2.1.8"
tier: core
protocol: modbus
connectivity: local
ders: [battery, meter]
control: false
size_bytes: 29105
sha256: "bd8fe1e850ce66e83e107116d7e236c499cca51f75872feb03efde58f95d6e41"
size_bytes: 29119
sha256: "5fc8e600eac7a70020e01e32c531f350f49bd076cac8a5598c2c06205b05f6b8"
- name: "pixii_pv"
version: "0.3.2"
tier: core
Expand Down
6 changes: 3 additions & 3 deletions manifests/pixii.yaml
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
name: "pixii"
version: "2.1.7"
version: "2.1.8"
tier: core
author: "Sourceful Labs AB and community contributors"
protocol: modbus
Expand All @@ -24,9 +24,9 @@ upstream_docs:
title: "SunSpec model 802: battery charge and control states"
kind: register_map
url_stability: stable
size_bytes: 29105
size_bytes: 29119
dkb_id: "pixii"
sha256: "bd8fe1e850ce66e83e107116d7e236c499cca51f75872feb03efde58f95d6e41"
sha256: "5fc8e600eac7a70020e01e32c531f350f49bd076cac8a5598c2c06205b05f6b8"
signature: ""

bytecode_sha256: ""
Expand Down
2 changes: 1 addition & 1 deletion support-status.json
Original file line number Diff line number Diff line change
Expand Up @@ -1136,7 +1136,7 @@
},
{
"catalog_source": true,
"catalog_version": "2.1.7",
"catalog_version": "2.1.8",
"driver_id": "pixii",
"targets": {
"blixt-l1": {
Expand Down
Loading