Original file line number Diff line number Diff line change
Expand Up @@ -117,7 +117,7 @@ The initial setup form includes the following options:
|--------|-------------|---------|
| **Panasonic ID** | Your Panasonic Comfort Cloud account ID | — |
| **Password** | Your Panasonic Comfort Cloud password | — |
| **Enable daily energy sensors** | Create daily energy and current power sensors | Disabled |
| **Enable daily energy sensors** | Create daily energy and current power sensors | Enabled |
| **Enable Nanoe switch for all devices** | Force the Nanoe switch to appear even if the device doesn't report Nanoe support | Disabled |
| **Use Panasonic preset names** | Use "Quiet" and "Powerful" instead of "Eco" and "Boost" preset names | Enabled |
| **Device fetch interval** | How often to poll device data (5–300 seconds) | 120s |
Expand All @@ -131,7 +131,7 @@ After initial setup, you can modify the following options from the integration's
| Option | Description | Default |
|--------|-------------|---------|
| **Force outside sensor** | Force the outside temperature sensor to appear even if no reading is available | Disabled |
| **Enable daily energy sensors** | Create daily energy and current power sensors | Disabled |
| **Enable daily energy sensors** | Create daily energy and current power sensors | Enabled |
| **Enable Nanoe switch for all devices** | Force the Nanoe switch to appear on all devices | Disabled |
| **Use Panasonic preset names** | Use "Quiet" and "Powerful" instead of "Eco" and "Boost" | Enabled |
| **Device fetch interval** | How often to poll device data (5–300 seconds) | 120s |
Expand Down Expand Up @@ -180,7 +180,7 @@ data:
- **No outside temperature** — Not all devices report outside temperature. Use the "Force outside sensor" option if you want the sensor entity to always appear.

### Energy Sensors
- **Energy data not updating** — Ensure "Enable daily energy sensors" is checked in the integration options. Note that energy data resets daily.
- **Energy data not updating** — Ensure "Enable daily energy sensors" is checked in the integration options. Energy sensors are on by default but can be disabled; disabling them helps accounts with many devices avoid Panasonic 429 rate limiting. Note that energy data resets daily.
- **Current power seems inaccurate** — Current power is extrapolated from the daily energy reading and may not reflect instantaneous power accurately.

---
Expand Down
2 changes: 1 addition & 1 deletion custom_components/panasonic_cc/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -18,7 +18,7 @@
CONF_FORCE_OUTSIDE_SENSOR = "force_outside_sensor"
DEFAULT_FORCE_OUTSIDE_SENSOR = False
CONF_ENABLE_DAILY_ENERGY_SENSOR = "enable_daily_energy_sensor"
DEFAULT_ENABLE_DAILY_ENERGY_SENSOR = False
DEFAULT_ENABLE_DAILY_ENERGY_SENSOR = True
CONF_USE_PANASONIC_PRESET_NAMES = "use_panasonic_preset_names"
DEFAULT_USE_PANASONIC_PRESET_NAMES = True
CONF_DEVICE_FETCH_INTERVAL = "device_fetch_interval"
Expand Down