You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
What steps will reproduce the problem?
1. Enable flow on a large production router having more than 10 Links with 50 -
100MBps terminated for remote location.
2. You would get flow files around 15 - 20 MB per minute.
3. CPU utilization is high when we start the flow-capture.
What is the expected output? What do you see instead?
I need to know how much flow rate was supported by flow-tools, and what is the
recommended server hardware platform to capture flow for nearly 50 routers on a
single server.
What version of the product are you using? On what operating system?
I am using flow-tools-0.68.5.1-1.el5 on Redhat enterprise linux 5 64 bit
Please provide any additional information below.
At present i am collecting flow data for one high utilization router with 10
Links on it, for this alone my server's load average is going to 3 - 5, i would
like to added more than 50 routers are the same server, can any one help me to
fine tune / suggest the hardware to handle the load..
My Server configuration :
CPU - 16 x 3.00GHz
MEMORY - 16 GB
HDD - 440 GB In RAID5 Array
Thanks in Advance,
Ram
Original issue reported on code.google.com by ramkuma...@gmail.com on 10 May 2013 at 4:37
This is not a 'defect,' and should probably have been posted to the mailing
list. However, your question is "How do I know I am getting all of the data?"
The following is taken directly from the SECURITY page on www.splintered.net"
"Loss of flow exports is usually a result of resource exhaustion on the
router, link to the flow collector, or the flow collector itself. "show
ip flow export" on the router will list some sources of lost flows. Check
output drops on the interface directly connected to the flow collector.
On 7500's the interface command "transmit-buffers backing-store"
can reduce output drops. Use netstat -s on the flow collector to display
UDP packets dropped due to full socket buffers. This is usually an indication
of an overworked server."
I successfully measured losses on an enterprise data collector by building a
second collector that was used to measure only one flow export. Then, choosing
a (sequence of) flow(s) that traversed two measurement points, I then
filtered/compared the traffic from the single-flow collector to the volume on
the aggregate (enterprise) collector, and was able to approximate lost flows.
I backed off feeds to the aggregate collector until the two reports were fairly
close in agreement.
Original comment by Seajay.T...@gmail.com on 28 Oct 2013 at 8:22
Activity
GoogleCodeExporter commentedon Feb 4, 2016
Original comment by
Seajay.T...@gmail.comon 28 Oct 2013 at 8:22