Notifications
You must be signed in to change notification settings - Fork 121
Feature negative dc charging #3795
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Draft
AlexanderHa98
wants to merge
10
commits into
openWB:master
Choose a base branch
from
AlexanderHa98:feature_negative_dc_charging
base: master
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
Draft
Changes from all commits
Commits
Show all changes
10 commits
Select commit
Hold shift + click to select a range
6b25cc2
Add Bidi to instant-charging
AlexanderHa98 02820e3
Save Zwischenstand
AlexanderHa98 bddd3c7
Fix counts in bidi
AlexanderHa98 04c0a5f
Fix Counter
AlexanderHa98 5d5463d
Refactor and Improve Bidi charging logic
AlexanderHa98 c77c482
Remove local debugging setup
AlexanderHa98 6e52bad
Add tests and fix bidi_charging
AlexanderHa98 5fe579b
Add Copilot suggestions
AlexanderHa98 6e43fff
Add requested changes
AlexanderHa98 5695be1
Remove unused import
AlexanderHa98 File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Gibt es einen Grund, dass Du nicht die Methode mode_and_counter_generator verwendest, Die auch min_current,.. verwenden, um über die Zähler zu iterieren?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Wenn ich
mode_and_counter_generatorverwende, schlägt der Testtest_cp3_cp4_bidi_dischargefehl.In dem Test wird geprüft, ob bei mehreren Bidi-CPs (im Zielladen) alle gleichmäßig entladen werden und nicht nur einer und die anderen nicht.
-> Deswegen habe ich das so gelöst. Ich brauche eine Liste mit allen CPs, die sich in diesem Mode befinden, um das Entladen entsprechend aufteilen zu können.