10 changes: 5 additions & 5 deletions CLAUDE.md
Original file line number Diff line number Diff line change
Expand Up @@ -54,7 +54,7 @@ menu model and its own platform layer, and the library brings everything else. T
- `TrayApp/Tray/TrayApplication.cs` - The Avalonia host: projects the menu model onto native menu items
and owns `HasStarted`
- `TrayApp/ConsoleRunner.cs` - The headless mode, including Ctrl+C and `SIGTERM`
- `TrayApp/Tray/ShutdownSignals.cs` - The tray mode's Ctrl+C and `SIGTERM`, turned into the Quit item's shutdown
- `TrayApp/Tray/ShutdownSignals.cs` - The tray mode's Ctrl+C, `SIGTERM` and `SIGHUP`, turned into the Quit item's shutdown
- `TrayApp/TrayIconSet.cs` - Loads the tray PNGs by embedded resource name, and says what the assembly
does have when a name misses
- `TrayApp/DesktopSession.cs` - Whether this process has a desktop session to put a tray icon in
Expand All @@ -69,7 +69,7 @@ menu model and its own platform layer, and the library brings everything else. T
without a panel
- `scripts/click-tray-menu.py` - Clicks an entry in a running tool's tray menu over D-Bus, and prints the
menu either side of it
- `scripts/check-tray-signals.sh` - Checks that `SIGTERM` and `SIGINT` end a tray run through `OnStop`
- `scripts/check-tray-signals.sh` - Checks that `SIGTERM`, `SIGINT` and `SIGHUP` end a tray run through `OnStop`
and the preference flush

### Dependencies
Expand Down Expand Up @@ -173,17 +173,17 @@ persisted toggle - the preference file lands under `~/.config`. Assertions on `T
this is what covers the projection onto native menu items.

`scripts/check-tray-signals.sh` covers the way out that does not go through the menu. It runs the demo in
the tray, clicks the remembered toggle, and sends `SIGTERM`, then `SIGINT`, inside the preference store's
the tray, clicks the remembered toggle, and sends `SIGTERM`, then `SIGINT`, then `SIGHUP`, inside the preference store's
500 ms debounce window:

```bash
dotnet build examples/TrayApp.Demo
dbus-run-session -- scripts/check-tray-signals.sh
```

Each run has to exit 0 and leave the toggle saved. An exit of 143 or 130 means the signal killed the
Each run has to exit 0 and leave the toggle saved. An exit of 143, 130 or 129 means the signal killed the
process outright, so the tool's `OnStop` never ran and the pending preference write was lost. Avalonia
handles neither signal, which is why `RunTray` holds a `ShutdownSignals` for the length of the run.
handles none of these signals, which is why `RunTray` holds a `ShutdownSignals` for the length of the run.

## Packaging

Expand Down
55 changes: 52 additions & 3 deletions TrayApp.Test/ShutdownSignalsTests.cs
Original file line number Diff line number Diff line change
Expand Up @@ -2,18 +2,22 @@

namespace ktsu.TrayApp.Test;

using System;
using System.Diagnostics;
using System.Runtime.InteropServices;
using System.Threading;
using ktsu.TrayApp;
using ktsu.TrayApp.Menu;
using ktsu.TrayApp.Tray;
using Microsoft.VisualStudio.TestTools.UnitTesting;

/// <summary>
/// Tests for how a tray run answers Ctrl+C and <c>SIGTERM</c>.
/// Tests for how a tray run answers Ctrl+C, <c>SIGTERM</c> and <c>SIGHUP</c>.
/// </summary>
/// <remarks>
/// The signals themselves are not sent: the handlers are called directly, so the tests show what each one
/// decides without a display or a process to kill. <c>scripts/check-tray-signals.sh</c> covers the real thing.
/// Most of these call the handlers directly, so they show what each one decides without a display or a process
/// to kill. The <c>SIGHUP</c> case sends the real signal, because what it checks is that the signal is taken at
/// all. <c>scripts/check-tray-signals.sh</c> covers the whole run.
/// </remarks>
[TestClass]
[DoNotParallelize]
Expand Down Expand Up @@ -51,6 +55,51 @@
Assert.IsFalse(host.RequestShutdown());
}

[TestMethod]
[OSCondition(OperatingSystems.Linux | OperatingSystems.OSX)]
public void HangupOnceTheTrayExists_IsTakenAndShutsTheTrayDown()
{
using TrayApplication host = Host();
int asked = 0;
using ShutdownSignals signals = new(() =>
{
Interlocked.Increment(ref asked);
return host;
});

// Keeps the test host alive whatever ShutdownSignals does: without it, a SIGHUP nothing takes ends the
// process, and the failure would show up as a crashed run instead of this assertion.
using ManualResetEventSlim delivered = new();
using PosixSignalRegistration guard = PosixSignalRegistration.Create(PosixSignal.SIGHUP, context =>
{
context.Cancel = true;
delivered.Set();
});

using (Process kill = Process.Start("kill", ["-HUP", Environment.ProcessId.ToString(System.Globalization.CultureInfo.InvariantCulture)]))
{
kill.WaitForExit();
Assert.AreEqual(0, kill.ExitCode);
}

Assert.IsTrue(delivered.Wait(TimeSpan.FromSeconds(10)), "SIGHUP was never delivered");

Check warning on line 85 in TrayApp.Test/ShutdownSignalsTests.cs

View check run for this annotation

SonarQubeCloud / SonarCloud Code Analysis

Consider using the overload that accepts a CancellationToken and pass 'TestContext.CancellationToken'

See more on https://sonarcloud.io/project/issues?id=ktsu-dev_TrayApp&issues=AaGJKa9ChVvDSLZmHgxB&open=AaGJKa9ChVvDSLZmHgxB&pullRequest=55
Assert.IsTrue(SpinWait.SpinUntil(() => Volatile.Read(ref asked) > 0, TimeSpan.FromSeconds(10)), "SIGHUP did not reach the tray");

// The signal already asked, so nothing is left for a second request to post.
Assert.IsFalse(host.RequestShutdown());
}

[TestMethod]
public void HangupBeforeTheTrayExists_IsLeftToEndTheProcess()
{
using ShutdownSignals signals = new(() => null);
PosixSignalContext context = new(PosixSignal.SIGHUP);

signals.OnTermination(context);

Assert.IsFalse(context.Cancel);
}

[TestMethod]
public void ARepeatedSignal_IsStillTakenButPostsNoSecondShutdown()
{
Expand Down
21 changes: 13 additions & 8 deletions TrayApp/Tray/ShutdownSignals.cs
Original file line number Diff line number Diff line change
Expand Up @@ -6,21 +6,24 @@ namespace ktsu.TrayApp.Tray;
using System.Runtime.InteropServices;

/// <summary>
/// Turns Ctrl+C and <c>SIGTERM</c> into the shutdown the tray's Quit item asks for, for as long as it is held.
/// Turns Ctrl+C, <c>SIGTERM</c> and <c>SIGHUP</c> into the shutdown the tray's Quit item asks for, for as long as
/// it is held.
/// </summary>
/// <remarks>
/// Avalonia handles neither signal, so without this a <c>kill</c>, a <c>systemctl stop</c> or a logout ended a
/// tray run through the runtime's default handler: the tool's stop action never ran, and a toggle clicked inside
/// the preference store's debounce window was never saved. Before the tray exists there is nothing to shut
/// Avalonia handles none of these signals, so without this a <c>kill</c>, a <c>systemctl stop</c>, a logout or
/// closing the terminal the tool was started from ended a tray run through the runtime's default handler: the
/// tool's stop action never ran, and a toggle clicked inside the preference store's debounce window was never
/// saved. Before the tray exists there is nothing to shut
/// down, so the signal is left to end the process as it would have.
/// </remarks>
internal sealed class ShutdownSignals : IDisposable
{
private readonly Func<TrayApplication?> host;
private readonly PosixSignalRegistration termination;
private readonly PosixSignalRegistration hangup;

/// <summary>
/// Initializes a new instance of the <see cref="ShutdownSignals"/> class, taking both signals.
/// Initializes a new instance of the <see cref="ShutdownSignals"/> class, taking all three signals.
/// </summary>
/// <param name="host">Reads the tray host, which does not exist until Avalonia has called back for it.</param>
internal ShutdownSignals(Func<TrayApplication?> host)
Expand All @@ -30,21 +33,23 @@ internal ShutdownSignals(Func<TrayApplication?> host)

Console.CancelKeyPress += OnCancelKeyPress;

// SIGTERM does not go through CancelKeyPress.
// SIGTERM and SIGHUP do not go through CancelKeyPress.
termination = PosixSignalRegistration.Create(PosixSignal.SIGTERM, OnTermination);
hangup = PosixSignalRegistration.Create(PosixSignal.SIGHUP, OnTermination);
}

/// <summary>
/// Releases both signals back to their default handling.
/// Releases all three signals back to their default handling.
/// </summary>
public void Dispose()
{
Console.CancelKeyPress -= OnCancelKeyPress;
termination.Dispose();
hangup.Dispose();
}

/// <summary>
/// Handles <c>SIGTERM</c>, keeping the process alive only when there is a tray to shut down instead.
/// Handles <c>SIGTERM</c> and <c>SIGHUP</c>, keeping the process alive only when there is a tray to shut down instead.
/// </summary>
/// <param name="context">The signal being delivered.</param>
internal void OnTermination(PosixSignalContext context) => context.Cancel = RequestShutdown();
Expand Down
4 changes: 2 additions & 2 deletions scripts/check-tray-signals.sh
Original file line number Diff line number Diff line change
@@ -1,7 +1,7 @@
#!/usr/bin/env bash
# Copyright (c) 2023-2026 ktsu-dev contributors
#
# Checks that a tray run ends through the tool's own shutdown when it is sent SIGTERM or SIGINT: the
# Checks that a tray run ends through the tool's own shutdown when it is sent SIGTERM, SIGINT or SIGHUP: the
# process exits 0 rather than dying to the signal, and a toggle clicked inside the preference store's
# 500 ms debounce window is still saved. Needs Xvfb, dbus-run-session and `pip install dbus-next`.
#
Expand Down Expand Up @@ -82,4 +82,4 @@ check() {
echo "SIG$signal: shut down cleanly and saved the toggle"
}

check TERM && check INT
check TERM && check INT && check HUP
Loading