GPUStack Operator makes GPUs, NPUs and other accelerators available to Kubernetes workloads. It discovers the hardware on each node, groups similar capacity into pools and uses Kueue to admit workloads when a pool has room.

Read the architecture overview to see how the pieces fit together, or browse the documentation.

Features

  • Heterogeneous Devices — discover accelerators across manufacturers and allocate whole devices, shared devices, logical slices or hardware partitions.
  • RDMA Networking — give workloads RDMA network interfaces alongside their accelerators.
  • Topology Management — place related workloads within the requested network or location domain.
  • KV Cache — share inference cache across workloads.
  • Model Delivery — fetch, verify and cache model weights on nodes before workloads need them.
  • Model Deployment — run model serving replicas with routing and optional prefill/decode roles.
  • Accelerated Instances — enter accelerator-backed container workspaces over SSH.

Installation

Use Kubernetes 1.29 or newer for scheduling and node model delivery, Helm 3.8 or newer, and cluster-admin access. The chart accepts Kubernetes 1.23 and newer, but simple allocation on 1.23–1.28 is untested; see version requirements.

Install the manufacturer's driver on each accelerator node. Some devices also need a container toolkit; see Vendor Prerequisites.

helm repo add gpustack https://docs.gpustack.ai/gpustack-operator/charts
helm install gpustack-operator gpustack/gpustack-operator \
  --namespace gpustack-system --create-namespace

The chart includes Node Feature Discovery, Kueue and the storage drivers. See Installation Modes if your cluster already runs any of them. For upgrades from v0.7.x or earlier, follow the subchart migration guide.

Uninstallation

helm uninstall gpustack-operator --namespace gpustack-system

Removing the bundled Kueue chart also removes its CRDs and the queues and workloads stored in them. To use a separately managed Kueue installation, install GPUStack with --set kueue.enabled=false. To remove resources created by the worker during uninstall, set cleanupOnUninstall=true when installing the chart.

Usage

The examples below assume a namespace named team-a, accelerator nodes with their drivers installed, and an InstanceType with available capacity. Replace the queue and InstanceType names with values from kubectl get instancetypes before applying a workload.

Heterogeneous Devices

kubectl get devices shows the discovered hardware. The ENTRANCE column of kubectl get instancetypes gives the queue name for a Pod. This one asks for a whole NVIDIA GPU:

apiVersion: v1
kind: Pod
metadata:
  name: gpu-workload
  namespace: team-a
  labels:
    kueue.x-k8s.io/queue-name: gpustack-fnv64-c4680bb149644f1c
spec:
  restartPolicy: Never
  containers:
    - name: worker
      image: ubuntu:24.04
      command:
        - "sleep"
        - "3600"
      resources:
        limits:
          nvidia.com/gpu: "1"

The queue name is an example; use the ENTRANCE of your chosen pool. See Accelerator Requests for shared, sliced and partitioned Pods.

RDMA Networking

To give that Pod a network endpoint, put both requests in the same container:

resources:
  limits:
    nvidia.com/gpu: "1"
    device.gpustack.ai/rdma.shared: "1"

This replaces the resources block above. A shared endpoint suits a container that needs one interface; use an exclusive request when it must be the adapter's only tenant. The node needs a usable endpoint, and NUMA alignment depends on its kubelet policy. See RDMA Operations for the other resource keys and checks.

Topology Management

When nodes already carry region and zone labels, an administrator can publish their hierarchy:

apiVersion: worker.gpustack.ai/v1
kind: TopologySource
metadata:
  name: cloud-zones
spec:
  nodeSelector: {}
  levels:
    - topology.kubernetes.io/region
    - topology.kubernetes.io/zone
  nodeLabels: {}

For a role whose replica spans multiple Pods, request one zone for each replica group:

roles:
  - name: server
    replicas: 2
    size: 4
    topology:
      requiredLevel: topology.kubernetes.io/zone

This is a role fragment; the engine still needs its own distributed execution settings. Use Topology Operations to verify the source and the Kueue topology before depending on that placement.

KV Cache

An administrator creates the store, its capacity pool and a grant for team-a, in that order:

apiVersion: worker.gpustack.ai/v1
kind: KVCacheBackend
metadata:
  name: mooncake-dram
spec:
  type: Mooncake
  connection:
    managed:
      leader: {}
      members:
        - nodeSelector:
            kubernetes.io/os: linux
          medium: DRAM
          capacityPerMember: 8Gi
---
apiVersion: worker.gpustack.ai/v1
kind: KVCachePool
metadata:
  name: shared-dram
spec:
  backends:
    - mooncake-dram
  quota:
    total: 8Gi
---
apiVersion: worker.gpustack.ai/v1
kind: KVCachePoolBinding
metadata:
  name: qwen-cache
  namespace: team-a
spec:
  poolRef:
    name: shared-dram
  quota:
    ceiling: 4Gi
  domain:
    blockSize: 64
    dtype: bfloat16

The ModelDeployment below names the binding, which grants this namespace access to the cache. Choose member nodes, quotas, block size and dtype for your engine before applying these resources. The KV Cache Walkthrough explains what to check at each step.

Model Delivery

A ModelArtifact names the weights that the serving workload will use:

apiVersion: worker.gpustack.ai/v1
kind: ModelArtifact
metadata:
  name: qwen-7b
  namespace: team-a
spec:
  source:
    huggingFace:
      repository: Qwen/Qwen2.5-7B-Instruct
      revision: main

The deployment below refers to this artifact. The operator resolves its revision before starting the serving Pods. Model Artifact covers PVC and image sources; Model Store Operations covers node delivery.

Model Deployment

This deployment uses the artifact and cache binding above. Replace instanceType with one from your cluster:

apiVersion: worker.gpustack.ai/v1
kind: ModelDeployment
metadata:
  name: qwen-chat
  namespace: team-a
spec:
  model:
    name: Qwen/Qwen2.5-7B-Instruct
    artifactRef:
      name: qwen-7b
  engine:
    name: vLLM
    version: "0.29.0"
  kvCache:
    poolRef:
      name: qwen-cache
  roles:
    - name: server
      replicas: 1
      instanceType: gpustack--nvidia-a10g-linux-amd64
      resources:
        accelerator: 1

For a standalone serving example, read Model Deployment. Prefill and Decode shows how to split the serving roles.

Accelerated Instances

Choose an InstanceType from the pool list whose SL capacity has room for a slice. Replace spec.type with that name and spec.data with your SSH public key. This workspace gives you SSH access to 20% of one accelerator's memory:

apiVersion: worker.gpustack.ai/v1
kind: InstanceSSHPublicKey
metadata:
  name: workspace-key
  namespace: team-a
spec:
  data: ssh-ed25519 <paste-your-public-key-here>
---
apiVersion: worker.gpustack.ai/v1
kind: Instance
metadata:
  name: sliced-demo
  namespace: team-a
spec:
  type: gpustack--nvidia-a10g-linux-amd64
  image: ubuntu:24.04
  command:
    - "tail"
    - "-f"
    - "/dev/null"
  sshPublicKey:
    name: workspace-key
  resources:
    accelerator: "1"
    acceleratorSlicedMemoryPercentage: 20
    acceleratorSlicedCoresPercentage: 100
  volume:
    ephemeral:
      capacity: 1Gi

Save it as instance.yaml, then run kubectl apply -f instance.yaml. Once the Pod is ready, forward its SSH port in one terminal and connect with the matching private key in another:

kubectl -n team-a wait --for=condition=Ready pod/sliced-demo --timeout=5m
kubectl -n team-a port-forward pod/sliced-demo 2222:22
ssh -i ~/.ssh/id_ed25519 -p 2222 root@127.0.0.1

The SSH session enters the workload container, where the accelerator and workspace are available. The walkthrough shows the resulting resources. Pods can request accelerators directly; see Accelerator Requests for complete manifests.

Accelerator Support

All manufacturers support whole-device and shared requests. Logical slicing shares a device through the manufacturer's software facilities. Physical partitioning uses hardware partitions enabled by an administrator; its availability depends on the device and its current mode.

Manufacturer Class Kubernetes resource Logical slicing Physical partitioning
AMD GPU amd.com/gpu Yes —
Cambricon MLU cambricon.com/mlu Yes —
Huawei Ascend NPU huawei.com/npu Yes —
Hygon DCU hygon.com/dcu Yes Yes (MIG)
Iluvatar GPU iluvatar.com/gpu Yes —
MetaX GPU metax-tech.com/gpu Yes —
Moore Threads GPU mthreads.com/gpu Yes —
NVIDIA GPU nvidia.com/gpu Yes Yes (MIG)
T-Head PPU alibabacloud.com/ppu Yes Yes (MIG)

A Pod requests one resource family in one container group. For NVIDIA, the request forms are:

Request resources.limits
Whole device nvidia.com/gpu: "1"
Shared device nvidia.com/gpu.shared: "1"
Logical slice nvidia.com/gpu.sliced: "1"
nvidia.com/gpu.sliced.memory-percentage: "20"
nvidia.com/gpu.sliced.cores-percentage: "40"
MIG partition nvidia.com/gpu.partitioned: "1"
nvidia.com/gpu.partitioned.mig-3g.40gb: "1"

See Accelerator Requests for the exact keys and rules, and Device Discovery for each manufacturer's slicing behavior.

License

Copyright (c) 2026 The GPUStack Authors. Licensed under the Apache License 2.0.

About

Provides a fantastic way to manage accelerator resources in Kubernetes.

Topics

Resources

Code of conduct

Contributing

Security policy

Stars

4 stars

Watchers

0 watching

Forks

Releases

Used by

Contributors

Languages