  • .165 (SSC335, sc2336) works again after a firmware update to 2.6.10.12: H.265 1920×1080 at 30 fps, RTSP checked (about 2.6 Mbit/s) and snapshot OK. On the old 2024-10 firmware the encoder produced no frames (SDP without parameter sets, MI_VENC … ring height is zero in dmesg).
  • The ninth cell of the 3×3 layout is the U cell (U cell: receive the pushed UDP RTP stream (udp://@:5600) in the ninth cell and the U view #87); .165 is a spare filler.
  • Note: load average ~10–11 is normal on SigmaStar SSC33x cameras.