Repository navigation
fix: menu can be operated with a remote control (#91) - #107
Conversation
…us from the layout to the active item (#91)
|
/review |
Code Review by Qodo
1.
|
…menu check in LABORATORY, Wi-Fi of Aceline-1 off (Qodo on #107)
|
Qodo review — decisions:
Also: LABORATORY notes that Wi‑Fi on Aceline-1 is switched off (wired only). |
Thanks for the update. The validation evidence addresses both open findings:
Noted that Aceline-1 was tested over wired Ethernet with Wi‑Fi disabled. |
…menu check in LABORATORY, Wi-Fi of Aceline-1 off (Qodo on #107)
fix: menu can be operated with a remote control (#91)
Closes #91.
Cause (reproduced on Aceline-1 with
input keyevent): the menu opens on OK, but the layout itself holds the focus (#65 gives it focus so that Escape works after a touch; on the AG-216 the popup also starts in touch mode). A D-pad key then searches for the next focusable view beside the focused one, and every item lies inside the layout's rectangle — so nothing ever got the focus, and OK/arrows did nothing.Fix
Device check:
input keyeventsequence OK → RIGHT ×n → DOWN → OK, in single view and multi-view (to be added to the next test round).