4 changes: 2 additions & 2 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -134,7 +134,7 @@ documents for different readers.
at all. Every pinned digest is also scanned weekly for fixable HIGH and
CRITICAL CVEs, and each image with findings has an open issue until a scan
finds it clean.
- **Documented decisions and runbooks.** 106 ADRs covering what was chosen
- **Documented decisions and runbooks.** 107 ADRs covering what was chosen
and what was rejected — including the costs accepted knowingly; 51
runbooks for the operations that are easy to get wrong at 1am, one of which
is the handover page a successor reads first. Every critical alert links to
Expand Down Expand Up @@ -229,7 +229,7 @@ inbound passes may still reach it. Data flow and the maintained Mermaid topology
│ ├── architecture.md network.md hardware.md
│ ├── observability.md security.md roadmap.md changelog.md
│ ├── diagrams/ # the network diagram (SVG) and its predecessors
│ ├── adr/ # 106 ADRs — architecture decision records
│ ├── adr/ # 107 ADRs — architecture decision records
│ ├── exercises/ # purple-team exercise records — see its README
│ └── runbooks/ # 51 runbooks; successor-handover.md is the front door
└── Makefile # make help
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -54,6 +54,15 @@ power source [#413](https://github.com/Gerrrt/HomeLab/issues/413) owed
> ([#421](https://github.com/Gerrrt/HomeLab/issues/421)). Each rule, export,
> alias and command below that names `.110` now names `.20`, and the decision
> is unchanged. The text below is left as written, per ADR-0001.
>
> **The `trinity` row, and the guest stop.** The last row of *Who shuts down*
> below, `trinity` *to be decided when it is placed*, is decided by
> [ADR-0107](0107-subscribe-trinity-to-the-ups-and-bound-saruman-s-guest-stop.md):
> it is on the PDU since the 2026-11-07 rack move and becomes a third
> secondary, on `10.0.99.1:3493`. The same ADR bounds `Saruman`'s ordered
> guests at `down=90`, and sizes the final low-battery duration from the worst
> case as well as the measured run, because *The low-battery point is the
> card's* below was written for two guests and `Saruman` now runs thirteen.

## Context

Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,144 @@
# ADR-0107: Subscribe `trinity` to the UPS, and bound `Saruman`'s guest stop

**Status:** Accepted · 2026-11 · decides the `trinity` row
[ADR-0049](0049-shut-down-on-the-ups-from-a-nut-server-on-the-firewall.md)
left open, and amends its low-battery reasoning for the guest set `Saruman`
now carries

## Context

ADR-0049's *Who shuts down* table ends with a row it could not fill:
*"`trinity`, when built — to be recorded when it is placed — to be decided
when it is placed."* It has been placed. The move into the 32U rack on
2026-11-06 and 2026-11-07
([#919](https://github.com/Gerrrt/HomeLab/issues/919),
[`move-into-the-32u-rack.md`](../runbooks/move-into-the-32u-rack.md)) put
`trinity` on PDU outlet 7. The same move put `gandalf` on outlet 8, the
console's brick on 9 and the KVM on 10, and `hardware.md` records it. The PDU
is UPS outlet group 1. So `trinity` is on the pack, and nothing tells it to
stop. A cut that outlasts the pack stops it hard.

`trinity` is the host where that costs most. It holds the household's own
data: Immich's library on a USB disk strapped to its tray, Paperless,
Vaultwarden, Memos and Actual, each with a database. Both disks are LUKS. It
is also AdGuard, the one forwarder behind `morpheus`'s resolver
([ADR-0055](0055-forward-to-adguard-alone.md)).

The second change is on `Saruman`. ADR-0049 was written for a hypervisor
with two guests, and the runbook's step 3.6 read both as `order=any`. Read on
2026-10-09 ([#574](https://github.com/Gerrrt/HomeLab/issues/574)),
it runs thirteen, and four of the six lab-domain guests are ordered
(`order=1..4,up=120`). Proxmox stops ordered guests one stage at a time and
allows each stage its `down` timeout, 180 s by default, before it moves on. The
last real shutdown, on 2026-10-06, stopped ten guests in 2 min 10 s:
32 s for the unordered group, then about 1 min 35 s for the four ordered
stages. That is the typical case. The worst case is a hung guest in every
stage: 180 s for the unordered group plus 4 × 180 s, about **15 minutes**, against
the 8 minutes of low-battery duration the card held when step 0 read it.
`ramuh` has hung after live snapshots before, so this is not hypothetical.

## Decision

**`trinity` becomes a third NUT secondary, on `morpheus`'s Winterfell
address, behind a pass/block pair in the same shape as the other two. The
four ordered guests on `Saruman` get `down=90`, and `Saruman`'s monitor
stays logged in until they are down. The card's low-battery duration is
raised to cover the worst case that remains before the window, not after
the one measured run, and the PDU's outlet group sheds on nothing.**

### `trinity` subscribes

| Host | Powered by | Acts on the signal | How | Rule it costs |
| --- | --- | --- | --- | --- |
| `trinity` | PDU outlet 7 | **Yes, first** | `nut-client` secondary against `10.0.99.1:3493`; `shutdown -h` stops Docker, which stops every container | A pass from `10.0.99.40` above a block from Winterfell, both to `10.0.99.1:3493`, on `igc0.99` |
| `gandalf` | PDU outlet 8 | No | The range is disposable ([ADR-0017](0017-buy-ifrit-for-iops-and-keep-the-range-disposable.md)) and off between sessions; nothing on it is the only copy of anything | None |
| The console and the KVM | PDU outlets 9 and 10 | No | No state to lose | None |
| The MokerLink at U14 | UPS outlet group 3 | No | Same as the TP-Link it replaced in ADR-0049's table | None |

Every other row of ADR-0049's table stands.

**It crosses nothing.** `trinity` and `morpheus` are both on Winterfell, so
the subscription reaches the firewall's own address on its own segment, as
`Saruman`'s and `smaug`'s do on theirs. `upsd` gains a third `LISTEN` line,
`10.0.99.1 3493`. It still binds no Hicks address and never the WAN.

**The pair narrows the listener, as ADR-0049's pairs do.** Without it, every
host on Winterfell could reach `10.0.99.1:3493` through the segment's egress
rule: `prometheus`, `oracle`, and the card itself. The pass from `10.0.99.40`
goes above a block from the Winterfell net, and both go above the egress
rule, beside *Block HTTPS to pfSense*. Hicks does not reach `10.0.99.1:3493`
either way: it reaches Winterfell on a named list
([ADR-0031](0031-narrow-hicks-to-a-named-list-on-winterfell-and-leave-the-lab-open.md)),
and 3493 is not on it.

**The same secondary login as the other two.** ADR-0049's argument holds: a
secondary can read status and cannot set `FSD`, so a second login would buy
separate revocation and nothing else. The primary's login stays on the
firewall.

### `Saruman`'s guest stop is bounded

Each of the four ordered guests gets `down=90` in its `startup:` line,
with its `order` and `up` kept as they are. A hung stage then costs 90 s, not
180. The worst case becomes 180 s (the unordered group, left at the default)
plus 4 × 90 s, plus the host's own halt: about **9½ minutes**. That is still
Comment thread
Gerrrt marked this conversation as resolved.
Resolved
more than 8. Every rebuild path sets the same string:
[`build-the-lab-domain.md`](../runbooks/build-the-lab-domain.md) and the
`startup_orders` output in `tofu/guests.tf` both carry `down=90`. A
rebuild that dropped it would quietly put each stage back to 180 s.

### `Saruman`'s monitor stays logged in until its guests are down

`morpheus` halts once its secondaries have logged out, with `HOSTSYNC` as
the ceiling on that wait. NUT's default is for a secondary's `upsmon` to exit
as soon as it has issued `SHUTDOWNCMD`. Systemd can also stop `nut-monitor`
before `pve-guests` has finished. Either way `Saruman` logs out at the start
of its halt, and the firewall then halts while guests are still stopping,
however large `HOSTSYNC` is. So `Saruman`'s `upsmon.conf` gets
`SHUTDOWNEXIT no` (NUT 2.8.1 and later), and a systemd drop-in orders
`nut-monitor` `Before=pve-guests.service`, which stops it after the guests.
`HOSTSYNC` then caps a wait that tracks the guests, and it goes to 600 s,
the bound above rounded up.

### The low-battery duration covers the worst case, from now on

ADR-0049 left the card's threshold to be read, then set from the measured
sequence. A run that went well, like 2026-10-06's, is shorter than what a
real cut can produce. The worst case to `morpheus` down is now about
**10½ minutes**: 9½ to `Saruman` down, `FINALDELAY 30`, and the firewall's
own halt. The duration is that plus half again, **16 minutes**. It is set
**before** the window (runbook §3.8), not after it: the 8 minutes on the
card today would run the pack out partway through a real cut. §6.5 then
keeps the larger of that rule and the measured run plus half again. At the
23 % load read on 2026-10-09, the card claims about 44 minutes of runtime,
so shutdown would begin a little under half an hour into a cut. That still
rides out every shorter cut, which is the property the pack was bought for.

For the same reason, **group 1, the PDU, sheds on nothing.** Any shed on time
on battery or on runtime remaining either cuts the PDU before the signal or
cuts it partway through the halt the duration was sized for. The runbook
turns every such setting off before step 5.

## Consequences

- **A third pass/block pair joins the ruleset**, on `igc0.99`. ADR-0013's
table gains it. Position is again the failure mode, and the proof is the
same as ADR-0049's: the block reads blocked from `prometheus`, with 53 open
as the control.
- **The house loses DNS filtering, and its forwarder, at the start of the
sequence instead of at the end.** `trinity` halts with the first group, and
`morpheus`'s resolver forwards to AdGuard alone, so names outside the
estate stop resolving while `Saruman`'s guests are still stopping. Nothing
in a halt needs them. The domain guests resolve through their own domain
controllers, and `morpheus`'s own records are local. Ordering `trinity`
after `Saruman` would need `upssched` on a secondary, and that is not worth
it for minutes of a cut that has already lasted half an hour.
- **`trinity` comes up second, after `morpheus`.** That is the order the move
runbook's §7 already uses. If the TPM does not unseal, the passphrase
prompt is on KVM port 7.
- **A hung guest is stopped hard after 90 s, not 180.** On a domain
controller that is a dirty stop, but a bounded one. The alternative is
the whole hypervisor losing power, which is worse.
- **This is a decision, not a build.** Nothing here is true on the hosts
until the runbook's step 4b and the 3.6 timeouts are applied and step 5
proves the order with three secondaries.
20 changes: 20 additions & 0 deletions docs/changelog.md
Original file line number Diff line number Diff line change
Expand Up @@ -19,6 +19,26 @@ docstring gives: it is a record, not a claim about now.

## 2026-11-08

- **[#574](https://github.com/Gerrrt/HomeLab/issues/574): the UPS shutdown
runbook re-read against the estate before its window, and `trinity`
decided.** Three things had moved since steps 0 to 4 were built on
2026-09-23. The rack move put `trinity`, `gandalf`, the console and the KVM
on the PDU. `Saruman` runs thirteen guests, four in ordered stages, so a
hung guest per stage could take about 15 minutes against the card's 8. The
UPS's outlet groups were found, with their shedding settings unread.
[ADR-0107](adr/0107-subscribe-trinity-to-the-ups-and-bound-saruman-s-guest-stop.md)
fills the `trinity` row ADR-0049 left open: it becomes a third secondary on
`10.0.99.1:3493` behind a pass/block pair on `igc0.99`, and the four ordered
guests get `down=90`, in the rebuild paths too. Review found that raising
`HOSTSYNC` could never have kept the firewall up while the guests stopped,
because `Saruman`'s monitor logs out at the start of its halt. So the
runbook now keeps it logged in (`SHUTDOWNEXIT no` and a `nut-monitor`
drop-in ordered before `pve-guests`) and sets `HOSTSYNC` to 600. That
leaves a worst case of about 10½ minutes to the firewall down. The card
goes to 16 minutes before the window rather than after it, and group 1
sheds on nothing. Nothing was changed on a host. Step 4b, the 3.6 to 3.8
changes and the outlet-group read are the first things the window does.

- **A copy run under the wrong `STACK` pruned five observability sets on
`oracle`, and `backup-volumes.sh` now refuses it.** `ScheduledJobStale`
fired for `backup-sensitive` and `verify-backups-sensitive` on `trinity`.
Expand Down
11 changes: 9 additions & 2 deletions docs/hardware.md
Original file line number Diff line number Diff line change
Expand Up @@ -60,6 +60,10 @@ that turns that estimate into a number is
move, `trinity`, `gandalf` and the console are on the PDU too, and `smaug` is on
it directly rather than by the long cord to the media room it had until
2026-11-06.
[ADR-0107](adr/0107-subscribe-trinity-to-the-ups-and-bound-saruman-s-guest-stop.md)
makes `trinity` a third host that halts on the signal. `gandalf`, the console
and the KVM do not. That subscription is the runbook's step 4b, and it is
not built yet.

Off-rack: only the eero Pro 6E units, distributed through the house.
Both laptops ride a mains cut out on their own cells, so each cell is a
Expand Down Expand Up @@ -168,10 +172,13 @@ spare.
group 1, both laptops' chargers on group 2, and the MokerLink on group 3. The
Smart-UPS X's card can switch and sequence each group separately, so the PDU
— and with it every host but the laptops — is one group. **Each group's
turn-off and turn-on settings are not read yet**: check them against the
shutdown in
turn-off, turn-on and load-shedding settings are not read yet**: check them
against the shutdown in
[ADR-0049](adr/0049-shut-down-on-the-ups-from-a-nut-server-on-the-firewall.md)
and the power-up order in the move runbook's §7, and write them here.
[`shut-down-on-the-ups.md`](runbooks/shut-down-on-the-ups.md) reads them
under *Before you start*, because shedding on group 1 would cut the PDU
before any host is told to halt.

**Two more decisions of 2026-10-16, both on the purchase table.** The UPS's
AP9641 card gets an APC AP9335T temperature probe, for rack ambient at the
Expand Down
11 changes: 8 additions & 3 deletions docs/roadmap.md
Original file line number Diff line number Diff line change
Expand Up @@ -53,9 +53,14 @@ Closes when it is empty.
UPS's signal.** Decided by
[ADR-0049](adr/0049-shut-down-on-the-ups-from-a-nut-server-on-the-firewall.md).
Steps 0–4 were built on 2026-09-23: NUT on `morpheus`, its rules, and
`Saruman` and `smaug` subscribed. The sequence is armed and not proved. The
gate is a rack visit, which proves the order with `upsmon -c fsd` and pulls
the mains once to replace the card's 47-minute claim with a number.
`Saruman` and `smaug` subscribed. The sequence is armed and not proved.
Since the rack move,
[ADR-0107](adr/0107-subscribe-trinity-to-the-ups-and-bound-saruman-s-guest-stop.md)
adds `trinity` as a third subscriber and caps `Saruman`'s ordered guests at
`down=90`, and neither is applied yet. The gate is a rack visit. It reads
the outlet groups, applies step 4b and steps 3.6 to 3.8, proves the order
with `upsmon -c fsd`, and pulls the mains once to replace the card's
47-minute claim with a number.
→ [runbook](runbooks/shut-down-on-the-ups.md)
- **[#1226](https://github.com/Gerrrt/HomeLab/issues/1226) The HomePods in
Home Assistant, for control.** Decided by
Expand Down
16 changes: 10 additions & 6 deletions docs/runbooks/build-the-lab-domain.md
Original file line number Diff line number Diff line change
Expand Up @@ -423,10 +423,10 @@ skips step 4.
same commands by guest name; run them as written here:

```bash
qm set 150 --startup order=1,up=120
qm set 151 --startup order=2,up=120
qm set 152 --startup order=3,up=120
qm set 153 --startup order=4,up=120
qm set 150 --startup order=1,up=120,down=90
qm set 151 --startup order=2,up=120,down=90
qm set 152 --startup order=3,up=120,down=90
qm set 153 --startup order=4,up=120,down=90
```

Check `qm config` for each one: the MAC, the `smbios1` UUID, `startup` on
Expand Down Expand Up @@ -536,7 +536,7 @@ for spec in "150 bahamut 4096 60 1" \
--scsi0 "large_data:$4,discard=on,iothread=1,ssd=1" \
--net0 virtio,bridge=vmbr0,firewall=0 \
--agent enabled=1 \
--onboot 1 --startup "order=$5,up=120" \
--onboot 1 --startup "order=$5,up=120,down=90" \
--ide2 local:iso/windows-server-2025-eval.iso,media=cdrom \
--ide0 local:iso/virtio-win.iso,media=cdrom \
--boot order='scsi0;ide2'
Expand Down Expand Up @@ -602,7 +602,11 @@ Six of those flags are worth knowing rather than copying.
- **`--balloon 0`.** Ballooning on a 128 GB host buys nothing here, and it makes
the guests' own memory metrics — which #266 will read — move for reasons that
are not the workload.
- **`--startup order=N,up=120` on the servers only.** The IOPS argument above.
- **`--startup order=N,up=120,down=90` on the servers only.** The IOPS
argument above. `down=90` caps each stage of the host's shutdown at 90 s,
and the UPS's low-battery budget counts on that
([ADR-0107](../adr/0107-subscribe-trinity-to-the-ups-and-bound-saruman-s-guest-stop.md)).
A rebuild that drops it puts each stage back to 180 s.
The endpoints get `--onboot 0` because ADR-0029 runs them per session; a
machine that comes back by itself is a machine that is not on demand.
- **`iothread=1` with `virtio-scsi-single`.** They pair, and `iothread` does