This pull request fixes issues in the spectral file generation workflow.

  • New function read_ckd_range in spectral.py to accurately read the wavenumber range from MT_CKD continuum files, ensuring that only valid bands are included for continuum calculations. Enhanced error handling when no valid bands are found.
  • Improved the handling of wavenumber resolution in Tmake_spectralfile.py by checking for consistency across volatiles.
  • Introduced a minimum temperature threshold for CIA calculations involving H2O, dropping unphysical low-temperature points.
  • Updated the version number to 2607.2 to reflect these changes.
  • Minor formatting changes to continuum data files for consistency in scientific notation.