Skip to content

Finalise the star shear-response test definition (star cutout vs input PSF) #772

Closed

Description

@cailmdaley

The star shear-response standing test (Tier-1 guardrail #763) needs its exact definition pinned. The star-response investigation showed the metacal response is ≈0 when the exact PSF (the star's own cutout) is used, and climbs at the bright end with the interpolated PSFEx model — so an "exact-cutout" test definition returns ≈0 by construction (trivially satisfiable), while an "input simulation PSF" definition measures something real but conflates PSF-model fidelity.

The open question (2026-06-23 tomography call): a definition that is both physically meaningful and not trivially satisfiable. The meeting proposed redefining the test to use the star cutout directly, to be settled offline.

Meeting record assigns this to Cail + Fabian. Feeds the Tier-1 guardrail #763 and the verification-suite epic #765.

— Claude on behalf of Cail

Activity

  1. cailmdaley commented on Jul 16, 2026

    @cailmdaley
    ContributorAuthor

    let's use the interpolated PSF model as fiducial, and ablate if we need to understand the problem

  2. cailmdaley commented on Sep 6, 2026

    @cailmdaley
    ContributorAuthor

    Decision (2026-07-16): the star shear-response test uses the interpolated PSF model as its fiducial input; the exact-cutout variant is kept as an ablation for when the bright-end response needs diagnosing. Closing; the test definition lives in #765.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment