Killswitch

Switching a capability off for every tenant during an incident, and switching it back. Decided in ADR-0101 § 13; the registry and the overlay are described in Feature Flags.

When to use it

Only during an incident, to stop an expensive or risky path for all tenants at once. It is not a way to take a feature away from one tenant; tenant flags and the plan do that.

Key Capability
killswitch.classroom.recording Recording a live class
killswitch.notifications.email Outbound email
killswitch.analytics.ingest Analytics ingest

No production code reads any of these yet. Flipping one is recorded and visible to the overlay, but changes no behavior until the capability that guards a path reads it. The owner of that capability states it in its own runbook.

What it needs

An operator holding the Platform permission platform.killswitch.write, a current token (see operator access), and the key from the table.

Switching a key off

PUT /api/platform/v1/killswitches/{key} with body {"enabled": false, "ticket": "INC-123"}, as shown in the operator access example. The answer is { "key", "before", "after", "correlationId" }. before is true when no row existed, because absent and enabled mean the same.

Concurrent flips of one key take turns on the row, so each answer's before is the previous flip's after, and a first flip of a key creates the row at the default before it reads it.

Two audit rows are written under the platform sentinel, which no tenant can read: the entry into the platform scope, and the result row tenancy.killswitch.toggle with the before and after state and the operator's digest. The ticket is on those rows. Find the rows by the correlation id. The switch's own row keeps no ticket, because the application role can read that table.

Reading the record

The sentinel rows are visible only to the learnstack_platform role (the table owner is filtered too, because row level security is forced), so a database administrator connects with the ConnectionStrings:PlatformAdmin credential to read them. By the correlation id the answer returned:

SELECT timestamp, operation, reason,
       metadata->'operator'->>'subjectDigest' AS operator_digest,
       metadata->'operator'->>'ticket' AS ticket,
       before_state, after_state
FROM audit_log
WHERE tenant_id = '00000000-0000-7000-8000-000000000002'
  AND correlation_id = '<correlationId>'
ORDER BY timestamp;

The operator is recorded as a digest, never as the raw sub. To find every row one operator wrote, compute their digest from the issuer and the sub (ISSUER must equal PlatformOperator:Issuer byte for byte, a trailing slash included) and filter on metadata->'operator'->>'subjectDigest':

printf 'learnstack.operator.subject.v1\n%s\n%s' "$ISSUER" "$SUB" \
  | openssl dgst -sha256 -binary | openssl base64 -A | tr '+/' '-_' | tr -d '='

The current state of a switch is its own row, if it has one:

SELECT key, is_enabled, toggled_at
FROM platform_killswitches WHERE key = '<key>';

When it takes effect

Immediately on the instance that handled the request, which drops its cached copy after the commit. Every other instance refreshes within 60 seconds. Plan for that minute. If the instance could not drop its copy it logs a Warning with event 7104, and then it too serves the old state for up to 60 seconds.

The read fails open. If the overlay cannot read the table or the cache, it answers the key's default, which is enabled. A switch flipped off during a database or cache incident can therefore read as on again once its cached copy expires. Watch the log for event 7107 (Error, "The killswitch overlay could not be read"), and repeat the flip if it appears. Event 7108 means a caller asked for a key that is not declared.

Switching it back

Send the same request with "enabled": true. There is no other restore, and no delete. Confirm by the response (after is true) and by the result row.

If the answer is not 200

Answer What happened What to do
400, 401, 403 The body, the ticket, the token or the grant See operator access
404 The key is not one of the three in the table, or no operator issuer is configured Check the spelling and the issuer setting
503 The audit row could not be written, so the table was not changed Repeat the request after Retry-After
500 Something failed unexpectedly: the platform credential is missing, or the final commit's outcome is unknown and the flip may have landed. The instance still dropped its cached copy Read the switch's row (above) before repeating

For a killswitch act, an admission with neither a matching results_total increment nor an audit_failures_total increment is an act whose outcome is unknown; read the row for it too. The onboarding acts are counted by acts_total and are not judged this way.

Not recoverable here

A flip is not undone by the audit log: the log records it, and only another flip reverses it. Both flips of a pair are in the audit log with their true before and after states.