Repository navigation
Commit 31b7c62
Place the vacuum mothers of the RB24/3 copper tubes and the RB24 valve flanges
This fixes air instead of vacuum inside the A-side beam pipe.
- RB24/3 built the vacuum mother voRB243CuTubeM but placed the bare copper tube, so its 2 x 298 cm bore was cave air.
- The valve placed RB24ValveFl instead of its vacuum mother RB24ValveFlI, leaving 2 x 1.5 cm of air.
- Both now place the mother. The Run 4 pipe gets the same RB24/3 fix.
- The mothers keep the outer shape of the parts they replace, so no new overlaps appear.
- The visibility call now hides voRB243CuTubeM instead of voRB24CuTubeM.